- Network Working Group K. McCloghrie
- Request for Comments: 1230 Hughes LAN Systems, Inc.
- R. Fox
- Synoptics, Inc.
- May 1991
-
-
- IEEE 802.4 Token Bus MIB
-
- Status of this Memo
-
- This memo defines a MIB for the IEEE 802.4 Token Bus for use with the
- SNMP protocol. This memo is a product of the Transmission Working
- Group of the Internet Engineering Task Force (IETF). This RFC
- specifies an IAB standards track protocol for the Internet community,
- and requests discussion and suggestions for improvements. Please
- refer to the current edition of the "IAB Official Protocol Standards"
- for the standardization state and status of this protocol.
- Distribution of this memo is unlimited.
-
- Table of Contents
-
- 1. Abstract .............................................. 1
- 2. The Network Management Framework....................... 2
- 3. Objects ............................................... 2
- 3.1 Format of Definitions ................................ 3
- 4. Overview .............................................. 3
- 4.1 Scope of Definitions ................................. 3
- 4.2 Textual Conventions .................................. 4
- 4.3 Optional Objects ..................................... 4
- 5. Definitions ........................................... 4
- 6. Acknowledgements ...................................... 22
- 7. References ............................................ 22
- 8. Security Considerations................................ 23
- 9. Authors' Addresses..................................... 23
-
- 1. Abstract
-
- This memo defines an experimental portion of the Management
- Information Base (MIB) for use with network management protocols in
- TCP/IP-based internets. In particular, this memo defines managed
- objects used for managing subnetworks which use the IEEE 802.4 Token
- Bus technology described in 802.4 Token-Passing Bus Access Method and
- Physical Layer Specifications, IEEE Standard 802.4.
-
-
-
-
-
-
-
- Transmission Working Group [Page 1]
-
- RFC 1230 IEEE 802.4 MIB May 1991
-
-
- 2. The Network Management Framework
-
- The Internet-standard Network Management Framework consists of three
- components. They are:
-
- RFC 1155 which defines the SMI, the mechanisms used for describing
- and naming objects for the purpose of management. RFC 1212
- defines a more concise description mechanism, which is wholly
- consistent with the SMI.
-
- RFC 1156 which defines MIB-I, the core set of managed objects for
- the Internet suite of protocols. RFC 1213, defines MIB-II, an
- evolution of MIB-I based on implementation experience and new
- operational requirements.
-
- RFC 1157 which defines the SNMP, the protocol used for network
- access to managed objects.
-
- The Framework permits new objects to be defined for the purpose of
- experimentation and evaluation.
-
- 3. Objects
-
- Managed objects are accessed via a virtual information store, termed
- the Management Information Base or MIB. Objects in the MIB are
- defined using the subset of Abstract Syntax Notation One (ASN.1) [7]
- defined in the SMI. In particular, each object has a name, a syntax,
- and an encoding. The name is an object identifier, an
- administratively assigned name, which specifies an object type. The
- object type together with an object instance serves to uniquely
- identify a specific instantiation of the object. For human
- convenience, we often use a textual string, termed the OBJECT
- DESCRIPTOR, to also refer to the object type.
-
- The syntax of an object type defines the abstract data structure
- corresponding to that object type. The ASN.1 language is used for
- this purpose. However, the SMI [3] purposely restricts the ASN.1
- constructs which may be used. These restrictions are explicitly made
- for simplicity.
-
- The encoding of an object type is simply how that object type is
- represented using the object type's syntax. Implicitly tied to the
- notion of an object type's syntax and encoding is how the object type
- is represented when being transmitted on the network.
-
- The SMI specifies the use of the basic encoding rules of ASN.1 [8],
- subject to the additional requirements imposed by the SNMP.
-
-
-
-
- Transmission Working Group [Page 2]
-
- RFC 1230 IEEE 802.4 MIB May 1991
-
-
- 3.1. Format of Definitions
-
- Section 5 contains contains the specification of all object types
- contained in this MIB module. The object types are defined using the
- conventions defined in the SMI, as amended by the extensions
- specified in [9,10].
-
- 4. Overview
-
- This memo defines three tables:
-
- - the 802.4 Operational Table containing state and
- operational parameter information which is specific to
- 802.4 interfaces;
-
- - the 802.4 Initialization Table containing the parameter
- information used by an 802.4 interface as the values to
- be assigned to its operational parameters upon
- initialization; and
-
- - the 802.4 Statistics Table containing 802.4 interface
- statistics.
-
- A managed system will have one entry in each of these tables for each
- of its 802.4 interfaces.
-
- This memo also defines OBJECT IDENTIFIERs, some to identify 802.4
- tests, for use with the ifExtnsTestTable defined in [11], and some to
- identify Token Bus interface Chip Sets, for use with the
- ifExtnsChipSet object defined in [11].
-
- 4.1. Scope of Definitions
-
- All objects defined in this memo are registered in a single subtree
- within the experimental namespace [3], and are for use with every
- interface which conforms to the IEEE 802.4 Token Bus Access Method
- [10]. At present, this applies to interfaces for which the ifType
- variable in the Internet-standard MIB [4,6] has the value:
-
- iso88024-tokenBus(8)
-
- For these interfaces, the value of the ifSpecific variable in the
- MIB-II [6] has the OBJECT IDENTIFIER value:
-
- dot4 OBJECT IDENTIFIER ::= { experimental 7 }
-
- as defined below.
-
-
-
-
- Transmission Working Group [Page 3]
-
- RFC 1230 IEEE 802.4 MIB May 1991
-
-
- 4.2. Textual Conventions
-
- Two new datatypes, MacAddress and OctetTime, are introduced as
- textual conventions in this document. These textual conventions have
- NO effect on either the syntax nor the semantics of any managed
- object. Objects defined using these conventions are always encoded by
- means of the rules that define their primitive type. Hence, no
- changes to the SMI or the SNMP are necessary to accommodate these
- textual conventions which are adopted merely for the convenience of
- readers and writers in pursuit of the elusive goal of a concise and
- unambiguous specification.
-
- 4.3. Optional Objects
-
- A few objects are defined in this memo with "optional" status for the
- purpose of allowing experimentation to determine whether they are
- useful or not. If sufficient consensus is reached in the Internet
- community to result in a subsequent revision of this memo being
- placed in the Internet-standard MIB, then these optional objects will
- either be removed or become mandatory.
-
- 5. Definitions
-
-
- RFC1230-MIB DEFINITIONS ::= BEGIN
-
- -- IEEE 802.4 Token Bus MIB
-
- IMPORTS
- experimental
- FROM RFC1155-SMI
- OBJECT-TYPE
- FROM RFC-1212;
-
- -- This MIB Module uses the extended OBJECT-TYPE macro as
- -- defined in [9].
-
-
-
- dot4 OBJECT IDENTIFIER ::= { experimental 7 }
-
- -- All representations of MAC addresses in this MIB Module
- -- use, as a textual convention (i.e. this convention does
- -- not affect their encoding), the data type:
-
- MacAddress ::= OCTET STRING (SIZE (6)) -- a 6 octet
- -- address in the
- -- "canonical" order
-
-
-
- Transmission Working Group [Page 4]
-
- RFC 1230 IEEE 802.4 MIB May 1991
-
-
- -- defined by IEEE
- -- 802.1a.
- -- 16-bit addresses, if needed, are represented by setting
- -- their upper 4 octets to all 0's, i.e., AAFF would be
- -- represented as 00000000AAFF.
-
-
- -- This specification follows the 802.4 convention of
- -- specifying time intervals, which are dependent on the
- -- bandwidth of the media, in units of octet time. One
- -- octet time is the time taken to transmit eight bits.
- -- Representation of such time intervals in this MIB Module
- -- use, as a textual convention (i.e., this convention does
- -- not affect their encoding), the data type:
-
- OctetTime ::= INTEGER -- the value of a time
- -- interval in units of octet
- -- time.
-
-
- -- The 802.4 Operational Table
-
- -- This table contains state and parameter information which
- -- is specific to 802.4 interfaces. It is mandatory that
- -- systems having 802.4 interfaces implement this table in
- -- addition to the generic interfaces table [4,6] and its
- -- generic extensions [11].
-
- dot4Table OBJECT-TYPE
- SYNTAX SEQUENCE OF Dot4Entry
- ACCESS not-accessible
- STATUS mandatory
- DESCRIPTION
- "This table contains Token Bus interface
- parameters and state variables, one entry
- per 802.5 interface."
-
- ::= { dot4 1 }
-
- dot4Entry OBJECT-TYPE
- SYNTAX Dot4Entry
- ACCESS not-accessible
- STATUS mandatory
- DESCRIPTION
- "A list of Token Bus status and operational
- parameter values for an 802.4 interface."
- INDEX { dot4IfIndex }
- ::= { dot4Table 1 }
-
-
-
- Transmission Working Group [Page 5]
-
- RFC 1230 IEEE 802.4 MIB May 1991
-
-
- Dot4Entry ::= SEQUENCE {
- dot4IfIndex
- INTEGER,
- dot4Options
- INTEGER,
- dot4State
- INTEGER,
- dot4Commands
- INTEGER,
- dot4MacAddrLen
- INTEGER,
- dot4NextStation
- MacAddress,
- dot4PreviousStation
- MacAddress,
- dot4SlotTime
- OctetTime,
- dot4LastTokenRotTime
- OctetTime,
- dot4HiPriTokenHoldTime
- OctetTime,
- dot4TargetRotTimeClass4
- OctetTime,
- dot4TargetRotTimeClass2
- OctetTime,
- dot4TargetRotTimeClass0
- OctetTime,
- dot4TargetRotTimeRingMaint
- OctetTime,
- dot4RingMaintTimerInitValue
- OctetTime,
- dot4MaxInterSolicitCount
- INTEGER (16..255),
- dot4MaxRetries
- INTEGER (0..7),
- dot4MinPostSilencePreambLen
- INTEGER,
- dot4StandardRevision
- INTEGER
- }
-
-
- dot4IfIndex OBJECT-TYPE
- SYNTAX INTEGER
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
- "The value of this object identifies the
-
-
-
- Transmission Working Group [Page 6]
-
- RFC 1230 IEEE 802.4 MIB May 1991
-
-
- 802.4 interface for which this entry
- contains management information. The
- value of this object for a particular
- interface has the same value as the
- ifIndex object, defined in [4,6], for the
- same interface."
- ::= { dot4Entry 1 }
-
- dot4Options OBJECT-TYPE
- SYNTAX INTEGER
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
- "The optional parts of the 802.4
- specification which are in use by this
- station. The options of the 802.4
- specification are represented by the
- following values:
- 1 - Priority
- 2 - Request-With-Response
- The value of this object is given by the
- sum of the above representations for
- those options in use on this interface.
- The value zero indicates that no options
- are in use."
- ::= { dot4Entry 2 }
-
- dot4State OBJECT-TYPE
- SYNTAX INTEGER {
- other(1),
- offline(2),
- outOfRing(3),
- enteringRing(4),
- inRing(5)
- }
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
- "The current state of the 802.4
- interface. The value of other(1) is
- used if the state is unknown
- (e.g., due to an error condition)."
- ::= { dot4Entry 3 }
-
- dot4Commands OBJECT-TYPE
- SYNTAX INTEGER {
- no-op(1),
- enterRing(2),
-
-
-
- Transmission Working Group [Page 7]
-
- RFC 1230 IEEE 802.4 MIB May 1991
-
-
- exitRing(3),
- reset(4),
- initialize(5)
- }
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "Setting this object causes the station
- to change the state of the interface as
- indicated by the specified value. An
- initialize(5) command causes the
- interfaceto load its operational
- parameters from its initialization
- parameters; the value of
- dot4InitInRingDesired determines
- whether the station tries to enter the
- logical ring immediately.
- Note that the 802.4 specification
- suggests a station remain Offline after a
- 'remote Network Management' reset(4),
- until a 'local Network Management'
- initialize(5) is performed.
- Setting this object to a value of
- no-op(1) has no effect. When read,
- this object always has the value no-op(1)."
- ::= { dot4Entry 4 }
-
- dot4MacAddrLen OBJECT-TYPE
- SYNTAX INTEGER {
- sixteenBit(1),
- forty-eightBit(2)
- }
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
- "This object indicates the size of MAC
- addresses interpreted by this station."
- ::= { dot4Entry 5 }
-
- dot4NextStation OBJECT-TYPE
- SYNTAX MacAddress
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
- "The MAC address of this station's
- successor in the logical ring."
- ::= { dot4Entry 6 }
-
-
-
-
- Transmission Working Group [Page 8]
-
- RFC 1230 IEEE 802.4 MIB May 1991
-
-
- dot4PreviousStation OBJECT-TYPE
- SYNTAX MacAddress
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
- "The source MAC address of the last token
- addressed to this station."
- ::= { dot4Entry 7 }
-
- dot4SlotTime OBJECT-TYPE
- SYNTAX OctetTime
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
- "The maximum time any station need wait
- for an immediate MAC-level response from
- another station.
- This value must the same in all stations on
- the 802.4 network."
- ::= { dot4Entry 8 }
-
- dot4LastTokenRotTime OBJECT-TYPE
- SYNTAX OctetTime
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
- "The observed token rotation time for the
- last token rotation, timed from token
- arrival to token arrival. A value of
- zero indicates that the token is not
- rotating."
- ::= { dot4Entry 9 }
-
- dot4HiPriTokenHoldTime OBJECT-TYPE
- SYNTAX OctetTime
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
- "The maximum duration for which a station
- can hold the token to transmit frames of
- access class 6 (if the priority option is
- implemented), or of any access class (if
- the priority option is not implemented)."
- ::= { dot4Entry 10 }
-
- dot4TargetRotTimeClass4 OBJECT-TYPE
- SYNTAX OctetTime
- ACCESS read-only
-
-
-
- Transmission Working Group [Page 9]
-
- RFC 1230 IEEE 802.4 MIB May 1991
-
-
- STATUS mandatory
- DESCRIPTION
- "If the priority scheme is being used,
- this value specifies a limit on how long
- a station can transmit frames at access
- class 4. The limit is measured from the
- time the station is able to start
- transmitting frames at this access class
- on one rotation, to the time it must stop
- transmitting frames at this access class
- on the next rotation. If the priority
- scheme is not being used, this object has
- the value 0."
- ::= { dot4Entry 11 }
-
- dot4TargetRotTimeClass2 OBJECT-TYPE
- SYNTAX OctetTime
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
- "If the priority scheme is being used,
- this value specifies a limit on how long
- a station can transmit frames at access
- class 2. The limit is measured from the
- time the station is able to start
- transmitting frames at this access
- class on one rotation, to the time it
- must stop transmitting frames at this
- access class on the next rotation. If
- the priority scheme is not being used,
- this object has the value 0."
- ::= { dot4Entry 12 }
-
- dot4TargetRotTimeClass0 OBJECT-TYPE
- SYNTAX OctetTime
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
- "If the priority scheme is being used,
- this value specifies a limit on how long
- a station can transmit frames at access
- class 0. The limit is measured from the
- time the station is able to start
- transmitting frames at this access
- class on one rotation, to the time it
- must stop transmitting frames at this
- access class on the next rotation. If
- the priority scheme is not being used,
-
-
-
- Transmission Working Group [Page 10]
-
- RFC 1230 IEEE 802.4 MIB May 1991
-
-
- this object has the value 0."
- ::= { dot4Entry 13 }
-
- dot4TargetRotTimeRingMaint OBJECT-TYPE
- SYNTAX OctetTime
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
- "A value used to limit the duration of a
- token rotation. If the duration of a
- token rotation exceeds this value, the
- station will not open the response window
- to solicit for a new successor."
- ::= { dot4Entry 14 }
-
- dot4RingMaintTimerInitValue OBJECT-TYPE
- SYNTAX OctetTime
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
- "The value to which the
- dot4TargetRotTimeRingMaint is set, each
- time the station enters the ring.
- A large value will cause the station to
- solicit successors immediately upon entry
- to the ring; a value of zero will cause
- the station to defer this solicitation
- for at least one token rotation."
- ::= { dot4Entry 15 }
-
- dot4MaxInterSolicitCount OBJECT-TYPE
- SYNTAX INTEGER (16..255)
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
- "The maximum number of consecutive token
- rotations without soliciting for a
- successor. If this count expires, the
- station opens the response window to
- solicit for a successor (providing the
- duration of the current token rotation
- has not exceeded
- dot4TargetRotTimeRingMaint). The least
- significant two bits of the count are
- determined randomly by the station on a
- per-use basis."
- ::= { dot4Entry 16 }
-
-
-
-
- Transmission Working Group [Page 11]
-
- RFC 1230 IEEE 802.4 MIB May 1991
-
-
- dot4MaxRetries OBJECT-TYPE
- SYNTAX INTEGER (0..7)
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
- "The maximum number of retries of a
- Request-with-Response (RWR) frame. If
- the RWR option is not in use, this object
- has the value 0."
- ::= { dot4Entry 17 }
-
- dot4MinPostSilencePreambLen OBJECT-TYPE
- SYNTAX INTEGER
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
- "The minimum number of octets of preamble
- on the first frame transmitted by this
- station after a period of 'transmitted'
- silence."
- ::= { dot4Entry 18 }
-
- dot4StandardRevision OBJECT-TYPE
- SYNTAX INTEGER {
- rev2(2)
- }
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
- "The Revision number of the 802.4 standard
- implemented by this station."
- ::= { dot4Entry 19 }
-
-
- -- 802.4 Initialization Table
-
- -- This table contains the parameter information used by an
- -- 802.4 interface as the values to be assigned to its
- -- operational parameters upon initialization. It is
- -- mandatory that systems having 802.4 interfaces implement
- -- this table.
-
- dot4InitTable OBJECT-TYPE
- SYNTAX SEQUENCE OF Dot4InitEntry
- ACCESS not-accessible
- STATUS mandatory
- DESCRIPTION
- "This table contains Token Bus
-
-
-
- Transmission Working Group [Page 12]
-
- RFC 1230 IEEE 802.4 MIB May 1991
-
-
- initialization parameters, one entry per
- 802.4 interface."
- ::= { dot4 2 }
-
- dot4InitEntry OBJECT-TYPE
- SYNTAX Dot4InitEntry
- ACCESS not-accessible
- STATUS mandatory
- DESCRIPTION
- "A list of Token Bus initialization
- parameters for an 802.4 interface."
- INDEX { dot4InitIfIndex }
- ::= { dot4InitTable 1 }
-
- Dot4InitEntry ::= SEQUENCE {
- dot4InitIfIndex
- INTEGER,
- dot4InitSlotTime
- OctetTime,
- dot4InitMaxInterSolicitCount
- INTEGER (16..255),
- dot4InitMaxRetries
- INTEGER (0..7),
- dot4InitHiPriTokenHoldTime
- OctetTime,
- dot4InitTargetRotTimeClass4
- OctetTime,
- dot4InitTargetRotTimeClass2
- OctetTime,
- dot4InitTargetRotTimeClass0
- OctetTime,
- dot4InitTargetRotTimeRingMaint
- OctetTime,
- dot4InitRingMaintTimerInitValue
- OctetTime,
- dot4InitMinPostSilencePreambLen
- INTEGER,
- dot4InitInRingDesired
- INTEGER
- }
-
- dot4InitIfIndex OBJECT-TYPE
- SYNTAX INTEGER
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
- "The value of this object identifies the
- 802.4 interface for which this entry
-
-
-
- Transmission Working Group [Page 13]
-
- RFC 1230 IEEE 802.4 MIB May 1991
-
-
- contains management information. The
- value of this object for a particular
- interface has the same value as the
- ifIndex object, defined in [4,6], for
- the same interface."
- ::= { dot4InitEntry 1 }
-
- dot4InitSlotTime OBJECT-TYPE
- SYNTAX OctetTime
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "The value assigned to the object
- dot4SlotTime when the station is
- initialized."
- ::= { dot4InitEntry 2 }
-
- dot4InitMaxInterSolicitCount OBJECT-TYPE
- SYNTAX INTEGER (16..255)
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "The value assigned to the object
- dot4MaxInterSolicitCount when the station
- is initialized."
- ::= { dot4InitEntry 3 }
-
- dot4InitMaxRetries OBJECT-TYPE
- SYNTAX INTEGER (0..7)
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "The value assigned to the object
- dot4MaxRetries when the station is
- initialized."
- ::= { dot4InitEntry 4 }
-
- dot4InitHiPriTokenHoldTime OBJECT-TYPE
- SYNTAX OctetTime
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "The value assigned to the object
- dot4HiPriTokenHoldTime when the station
- is initialized."
- ::= { dot4InitEntry 5 }
-
-
-
-
-
- Transmission Working Group [Page 14]
-
- RFC 1230 IEEE 802.4 MIB May 1991
-
-
- dot4InitTargetRotTimeClass4 OBJECT-TYPE
- SYNTAX OctetTime
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "The value assigned to the object
- dot4TargetRotTimeClass4 when the station
- is initialized."
- ::= { dot4InitEntry 6 }
-
- dot4InitTargetRotTimeClass2 OBJECT-TYPE
- SYNTAX OctetTime
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "The value assigned to the object
- dot4TargetRotTimeClass2 when the station
- is initialized."
- ::= { dot4InitEntry 7 }
-
- dot4InitTargetRotTimeClass0 OBJECT-TYPE
- SYNTAX OctetTime
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "The value assigned to the object
- dot4TargetRotTimeClass0 when the station
- is initialized."
- ::= { dot4InitEntry 8 }
-
- dot4InitTargetRotTimeRingMaint OBJECT-TYPE
- SYNTAX OctetTime
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "The value assigned to the object
- dot4TargetRotTimeRingMaint when the station
- is initialized."
- ::= { dot4InitEntry 9 }
-
- dot4InitRingMaintTimerInitValue OBJECT-TYPE
- SYNTAX OctetTime
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "The value assigned to the object
- dot4RingMaintTimerInitValue when the
- station is initialized."
-
-
-
- Transmission Working Group [Page 15]
-
- RFC 1230 IEEE 802.4 MIB May 1991
-
-
- ::= { dot4InitEntry 10 }
-
- dot4InitMinPostSilencePreambLen OBJECT-TYPE
- SYNTAX INTEGER
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "The value assigned to the object
- dot4MinPostSilencePreambLen when the
- station is initialized."
- ::= { dot4InitEntry 11 }
-
- dot4InitInRingDesired OBJECT-TYPE
- SYNTAX INTEGER {
- inRing(1),
- outOfRing(2)
- }
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "This object determines whether the
- station will attempt to enter the logical
- ring immediately after initialization."
- ::= { dot4InitEntry 12 }
-
-
- -- 802.4 Statistics Table
-
- -- This table contains Token Bus statistics, one entry per
- -- 802.4 interface. It is mandatory that systems having
- -- 802.4 interfaces implement this table.
-
- dot4StatsTable OBJECT-TYPE
- SYNTAX SEQUENCE OF Dot4StatsEntry
- ACCESS not-accessible
- STATUS mandatory
- DESCRIPTION
- "A table containing Token Bus statistics.
- All the statistics are defined using the
- syntax Counter as 32 bit wrap around
- counters. Thus, if an interface's
- hardware chip set maintains these
- statistics in 16-bit counters, then the
- agent must read the hardware's counters
- frequently enough to prevent loss of
- significance, in order to maintain
- a 32-bit counter in software."
- ::= { dot4 3 }
-
-
-
- Transmission Working Group [Page 16]
-
- RFC 1230 IEEE 802.4 MIB May 1991
-
-
- dot4StatsEntry OBJECT-TYPE
- SYNTAX Dot4StatsEntry
- ACCESS not-accessible
- STATUS mandatory
- DESCRIPTION
- "An entry containing the 802.4 statistics
- for a particular interface."
- INDEX { dot4StatsIfIndex }
- ::= { dot4StatsTable 1 }
-
- Dot4StatsEntry ::= SEQUENCE {
- dot4StatsIfIndex
- INTEGER,
- dot4StatsTokenPasses
- Counter,
- dot4StatsTokenHeards
- Counter,
- dot4StatsNoSuccessors
- Counter,
- dot4StatsWhoFollows
- Counter,
- dot4StatsTokenPassFails
- Counter,
- dot4StatsNonSilences
- Counter,
- dot4StatsFcsErrors
- Counter,
- dot4StatsEbitErrors
- Counter,
- dot4StatsFrameFrags
- Counter,
- dot4StatsFrameTooLongs
- Counter,
- dot4StatsOverRuns
- Counter,
- dot4StatsDupAddresses
- Counter
- }
-
- dot4StatsIfIndex OBJECT-TYPE
- SYNTAX INTEGER
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
- "The value of this object identifies the
- 802.4 interface for which this entry
- contains management information. The
- value of this object for a particular
-
-
-
- Transmission Working Group [Page 17]
-
- RFC 1230 IEEE 802.4 MIB May 1991
-
-
- interface has the same value as the
- ifIndex object, defined in [4,6], for the
- same interface."
- ::= { dot4StatsEntry 1 }
-
- dot4StatsTokenPasses OBJECT-TYPE
- SYNTAX Counter
- ACCESS read-only
- STATUS optional
- DESCRIPTION
- "The number of times this station has
- passed the token."
- ::= { dot4StatsEntry 2 }
-
- dot4StatsTokenHeards OBJECT-TYPE
- SYNTAX Counter
- ACCESS read-only
- STATUS optional
- DESCRIPTION
- "The number of tokens heard by this
- station."
- ::= { dot4StatsEntry 3 }
-
- dot4StatsNoSuccessors OBJECT-TYPE
- SYNTAX Counter
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
- "The number of times the station could
- not find a successor while believing
- itself not the only station in the ring.
- This can signify a faulty transmitter
- condition in this station."
- ::= { dot4StatsEntry 4 }
-
- dot4StatsWhoFollows OBJECT-TYPE
- SYNTAX Counter
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
- "The number of times the station has had
- to look for a new next station."
- ::= { dot4StatsEntry 5 }
-
- dot4StatsTokenPassFails OBJECT-TYPE
- SYNTAX Counter
- ACCESS read-only
- STATUS mandatory
-
-
-
- Transmission Working Group [Page 18]
-
- RFC 1230 IEEE 802.4 MIB May 1991
-
-
- DESCRIPTION
- "The number of times the station failed in
- passing the token to the next station."
- ::= { dot4StatsEntry 6 }
-
- dot4StatsNonSilences OBJECT-TYPE
- SYNTAX Counter
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
- "The number of occurrences of non-silence
- followed by silence in which a start
- delimiter was not detected."
- ::= { dot4StatsEntry 7 }
-
- dot4StatsFcsErrors OBJECT-TYPE
- SYNTAX Counter
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
- "The number of frames received with an
- incorrect FCS and the E-bit reset."
- ::= { dot4StatsEntry 8 }
-
- dot4StatsEbitErrors OBJECT-TYPE
- SYNTAX Counter
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
- "The number of frames the station
- received with the E-bit set in the
- end delimiter."
- ::= { dot4StatsEntry 9 }
-
- dot4StatsFrameFrags OBJECT-TYPE
- SYNTAX Counter
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
- "The number of occurrences of receiving a
- start delimiter followed by another start
- delimiter, an invalid symbol sequence or
- silence, without an intervening end
- delimiter."
- ::= { dot4StatsEntry 10 }
-
- dot4StatsFrameTooLongs OBJECT-TYPE
- SYNTAX Counter
-
-
-
- Transmission Working Group [Page 19]
-
- RFC 1230 IEEE 802.4 MIB May 1991
-
-
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
- "The number of frames that were received
- that were larger than the media's MTU."
- ::= { dot4StatsEntry 11 }
-
- dot4StatsOverRuns OBJECT-TYPE
- SYNTAX Counter
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
- "The number of times a FIFO overrun was
- detected in the station."
- ::= { dot4StatsEntry 12 }
-
- dot4StatsDupAddresses OBJECT-TYPE
- SYNTAX Counter
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
- "The number of times this station
- detected another station using the same
- MAC address."
- ::= { dot4StatsEntry 13 }
-
-
- -- 802.4 Interface Tests
-
- dot4Tests OBJECT IDENTIFIER ::= { dot4 5 }
-
- -- The extensions to the interfaces table proposed in [11]
- -- define a table object, ifExtnsTestTable, through which a
- -- network manager can instruct an agent to test an interface
- -- for various faults. A test to be performed is identified
- -- (as the value of ifExtnsTestType) via an OBJECT IDENTIFIER.
-
- -- When a test fails, the object ifExtnsTestCode, defined in
- -- [11], may contain a media-specific error-code. For 802.4
- -- interfaces, the following is defined as the value of
- -- ifExtnsTestCode when a test fails because the modem could
- -- not be initialized:
-
- dot4Errors OBJECT IDENTIFIER ::= { dot4 4 }
- dot4ModemInitFailed OBJECT IDENTIFIER ::= { dot4Errors 1 }
-
- -- The Full-Duplex Loop Back Test is a common test, defined
- -- in [11] as:
-
-
-
- Transmission Working Group [Page 20]
-
- RFC 1230 IEEE 802.4 MIB May 1991
-
-
- --
- -- testFullDuplexLoopBack
- --
- -- Invoking this test on a 802.4 interface causes the
- -- interface to check the path from memory through the chip
- -- set's serial interface back to memory, thus checking the
- -- proper functioning of the transmit and receive machines
- -- of the token bus hardware.
- -- This test may only be invoked when the interface is
- -- the Offline state.
-
- -- The FIFO Path test is defined by:
-
- testFifoPath OBJECT IDENTIFIER ::= { dot4Tests 1 }
-
- -- Invoking this test causes the interface to check the path
- -- from memory to the chip set's FIFO and back to memory.
- -- This test checks the hosts interface to the token bus
- -- hardware. This test may only be invoked when the
- -- interface is the Offline state.
-
- -- The External Loopback test is defined by:
-
- testExternalLoopback OBJECT IDENTIFIER ::= { dot4Tests 2 }
-
- -- Invoking this test causes the interface to check the path
- -- from memory through the chip set and out onto the network
- -- for external (e.g., at the head-end) loopback through the
- -- chip set to memory. This test checks the host's interface
- -- to the 802.4 network. This test is liable to cause
- -- serious disruption if invoked on an operational network.
-
-
-
- -- 802.4 Hardware Chip Sets
-
- dot4ChipSets OBJECT IDENTIFIER ::= { dot4 6 }
-
- -- The extensions to the interfaces table proposed in [11]
- -- define an object, ifExtnsChipSet, with the syntax of
- -- OBJECT IDENTIFIER, to identify the hardware chip set in
- -- use by an interface. That definition specifies just
- -- one applicable object identifier:
- --
- -- unknownChipSet
- --
- -- for use as the value of ifExtnsChipSet when the specific
- -- chip set is unknown.
-
-
-
- Transmission Working Group [Page 21]
-
- RFC 1230 IEEE 802.4 MIB May 1991
-
-
- --
- -- This MIB defines the following for use as values of
- -- ifExtnsChipSet:
- -- for use as values of ifExtnsChipSet
-
- -- Motorola 68824 Token Bus Controller
- chipSetMc68824 OBJECT IDENTIFIER ::= { dot4ChipSets 1 }
-
- END
-
- 6. Acknowledgements
-
- This document was produced under the auspices of the IETF's
- Transmission Working Group. The comments of the following
- individuals are acknowledged:
-
- Brian Kline, Hughes LAN Systems, Inc.
- Bruce Lieberman, Hughes LAN Systems, Inc.
- Marshall T. Rose, Performance Systems International, Inc.
-
- 7. References
-
- [1] Cerf, V., "IAB Recommendations for the Development of Internet
- Network Management Standards", RFC 1052, NRI, April 1988.
-
- [2] Cerf, V., "Report of the Second Ad Hoc Network Management Review
- Group", RFC 1109, NRI, August 1989.
-
- [3] Rose M., and K. McCloghrie, "Structure and Identification of
- Management Information for TCP/IP-based internets", RFC 1155,
- Performance Systems International, Hughes LAN Systems, May 1990.
-
- [4] McCloghrie K., and M. Rose, "Management Information Base for
- Network Management of TCP/IP-based internets", RFC 1156, Hughes
- LAN Systems, Performance Systems International, May 1990.
-
- [5] Case, J., Fedor, M., Schoffstall, M., and J. Davin, "Simple
- Network Management Protocol (SNMP), RFC 1157, SNMP Research,
- Performance Systems International, Performance Systems
- International, MIT Laboratory for Computer Science, May 1990.
-
- [6] McCloghrie K., and M. Rose, Editors, "Management Information Base
- for Network Management of TCP/IP-based internets", RFC 1213,
- Performance Systems International, March 1991.
-
- [7] Information processing systems - Open Systems Interconnection -
- Specification of Abstract Syntax Notation One (ASN.1),
- International Organization for Standardization, International
-
-
-
- Transmission Working Group [Page 22]
-
- RFC 1230 IEEE 802.4 MIB May 1991
-
-
- Standard 8824, December 1987.
-
- [8] Information processing systems - Open Systems Interconnection -
- Specification of Basic Encoding Rules for Abstract Notation One
- (ASN.1), International Organization for Standardization,
- International Standard 8825, December 1987.
-
- [9] Rose, M., and K. McCloghrie, Editors, "Concise MIB Definitions",
- RFC 1212, Performance Systems International, Hughes LAN Systems,
- March 1991.
-
- [10] Token-Passing Bus Access Method and Physical Layer
- Specifications, Institute of Electrical and Electronic Engineers,
- IEEE Standard 802.4, May 1988.
-
- [11] McCloghrie, K., Editor, "Extensions to the Generic-Interface
- MIB", RFC 1229, Hughes LAN Systems, May 1991.
-
- 8. Security Considerations
-
- Security issues are not discussed in this memo.
-
- 9. Authors' Addresses
-
- Keith McCloghrie
- Hughes LAN Systems, Inc.
- 1225 Charleston Road
- Mountain View, CA 94043
-
- Phone: (415) 966-7934
- EMail: kzm@hls.com
-
-
- Richard Fox
- Synoptics, Inc.
- 4401 Great America Pkwy
- PO Box 58185
- Santa Clara, Cal. 95052
-
- Phone: (408) 764-1372
- EMail: rfox@synoptics.com
-
-
-
-
-
-
-
-
-
-